• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Philips Respironics V60 Ventilator

Philips Respironics V60 Ventilator

Brand:   Philips
Condition:   SellerRefubrished
The Respironics V60 Ventilator combines Respironics’ ventilation expertise with Philips’ focus on simplifying advanced health care.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

More Philips Respironics V60 Pictures Philips Respironics V60 - Soma Technology, Inc.Philips V60 Ventilator - Soma Technology, Inc.Respironics V60 - Soma Technology, Inc. Philips Respironics V60 Features The Respironics V60 Ventilator combines Respironics’ ventilation expertise with Philips’ focus on simplifying advanced health care. The result is the noninvasive ventilation gold standard with an invasive ventilation safety net and an interactive display that helps simplify patient management. Because every breath matters and every breath is different, patients need a ventilator that always follows their breathing pattern, whatever their acuity. The Respironics V60 uses auto-adaptive technology to help ensure patient synchrony and therapy acceptance. Improved signal processing technology is finely tuned for both adult and pediatric patients. High resolution graphics facilitating waveform interpretation. Internal 6-hour battery enables intra-hospital transport (actual battery time will vary depending on user settings and battery charge level). Standby mode supports patient-clinician interaction without nuisance alarms. Data communication capabilities support hospital connectivity. Respi-Link, a remote communication tool, allows efficient system diagnostics and upgrades via internet. AVAPS maintains a target tidal volume in a pressure limited mode. It provides extra assurance similar to a volume limited mode with the safety of a pressure limited mode. CPAP with C-Flex offers three levels of flow-based expiratory pressure relief. This option leads to improved sleep quality and patient comfort, adding greater flexibility and improved treatment acceptance. PCV can be used when greater control of the patient's breathing pattern is required. Additionally, the option of ventilating a patient invasively gives the caregiver greater flexibility in the approach to treatment. ICU-grade NIV performance with enhanced safety and monitoring. ‡Treatment for a wide range of clinical severities and patients from pediatric to adult. Flexibility for intra-hospital transport with an internal 6-hour smart battery. Respironics V60 Specifications Patient Types Adult Pediatric •(Less than or equal to 20 kg) Modes Continuous positive airway pressure (CPAP) Spontaneous with timed backup (S/T) Pressure control ventilation (PCV) Average volume assured pressure support (AVAPS) —optional Settings C-Flex OFF, 1–3 CPAP 4–25 cmH2O EPAP 4–25 cmH2O IPAP 4–40 cmH2O I-time (inspiratory time) 0.30–3.00 sec Max P (AVAPS maximum IPAP) 6–40 cmH2O Min P (AVAPS minimum IPAP) 5–30 cmH2O O2 (oxygen percent) 21–100% Ramp time OFF, 5–45 min Rate (respiratory rate) 4–60 BPM Rise (rise time) 1–5 Triggering and cycling Auto-adaptive (Auto-Trak) AVAPS target tidal volume 200–2000 ml Monitored Parameters Breath Phase / Trigger Indicator Spont, Timed, Exhale PIP 0–50 cmH2O Patient / Total Leak 0-200 l/min BTPS Patient trigger 0–100% Respiratory rate 0–90 BPM Ti/Ttot 0–91% Minute volume ²OPLQ%736 Tidal volume 0–3000 ml BTPS General Oxygen inlet pressure range 276–600 kPa (40–87 psig) Weight 10.9 kg (24lb) with optional battery; 10.0 kg (22 lb) without optional battery Dimensions 33.7 cm (13.3 in) height; 39.4cm (15.5 in) weight; 42.9 cm (16.5 in) depth Electrical AC voltage 100–240 VAC AC frequency 50–60 Hz AC power 300 VA Battery operating time 6 hours in normal conditions

Additional Information

General Information About Ventilators Mechanical Ventilation Use of a machine to induce alternating inflation and deflation of the lungs with air Regulates Oxygen/CO2 levels in blood Volume and Pressure of Air forced into Lungs is controlled Has to meet varying demands of patient ventilation Modes of Ventilation Volume control Pressure control CPAP/BIPAP Support Ventilation Combination Of Modes Intermittent mandatory Ventilation Components of Ventilator System Compressed Gas Source Patient Breathing Circuit Mixer/Blender Hoses Optional monitoring O2 Volume Classification Driving Mechanism Pneumatic (Mark 7) Electronic (Siemens 900C)Function Respirators: Short time ventilator support Conventional Ventilators :long term, advance Support Portability Transport/battery backup Patients Adult Pediatric Or Neonatal Technologies Turbine technology High-Frequency Oscillatory ventilation Modes IMV, SIMV, PC, VC, S/T etc. MRI Compatible (Non ferromagnetic components) Flow Sensors- Volume Measurements Pressure transducers Questions about our Ventilators? Soma Technology, Inc offers a wide range of Ventilators. If you have any questions about any of our Ventilators or need a quick quote, call 1-800-GET-SOMA and one of our knowledgeable sales representatives will help you.