• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
GE Dash 3000 Multiparameter Monitor

GE Dash 3000 Multiparameter Monitor

Brand:   GE
Condition:   SellerRefubrished
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

GE Dash 3000 Features: Durable design creates a dependable solution for demanding transport applications, including air transport. System consistently produces the most accurate, reliable NIBP information. Ideally suited for NICU, PICU and hypertensive patients. GE Dash 3000 Specifications: Dimensions Height: 26 cm. Depth: 20 cm. Width: 28 cm Weight: 5.5 kg Display Size: 22 cm (diagonal). Type: active-matrix color TFT. Resolution: 640 x 480 pixels. Number of traces: 6 maximum. Number of seconds/trace: 4.9 at 25 mm/sec. Sweep Speed: 6.25, 12.5, 25 mm/sec (with erase bar). Information window:displays non-real-time information without obstructing the display of real-time information. Display organization: prioritized by parameter. Controls Trim Knob® control. Five hard keys: Silence Alarm, Graph Go/Stop, NIBP Go/Stop, function (zero all) and Power On/Off. Alarms Categories: patient status and system status. Priority: 4-levels crisis, warning, advisory, message. Notification: audible and visual. Settings:default or user-defined. Silencing: 1 minute, current alarm only. Pause: 5 minutes in adult ICU mode, 3 minutes in Neonatal ICU mode, and 5, 15, minutes or permanent pause in OR mode. ECG Standard leads available: I, II, III, V, aVR, aVL, and aVF. Leads analyzed simultaneously: I, II, III and V (multi-lead). Lead fail: identifies failed lead. Alarms: user-selectable upper and lower heart rate limits. Respiration Measurement technique: impedance variation detection. Range respiration rate: 0-200 breaths per minute. User-selectable upper and lower respiration rate limits, and user-selectable apnea limit. Temperature Number of channels: 2. Resolution: ±0.1°C. Alarms: user-selectable upper and lower limits for T1, T2. Invasive Blood Pressure Number of channels: 2. Range: -25mmHg to 300mmHg. Alarms: user-selectable upper and lower limits for systolic, diastolic, and mean pressures. NIBP Measurement technique: oscillometric. Displayed parameters: systolic, diastolic, and mean pressures, time of last measurement. Measurement modes: manual, auto, and stat in Adult ICU and OR modes, manual and auto in neonatal mode. Systolic range: 30-275 mmHg adult, 30-235 mmHg pediatric, 30-135 mmHg neonate. Diastolic range: 10-220mmHg adult, 10-220mmHg pediatric, 10-110 mmHg neonate. Pulse Oximetry Parameters monitored: SpO2 and peripheral pulse rate. SpO2 range: 50-100%. PPR range: 30-300 beats per minute. SpO2 accuracy: ±2%, 70 – 100% SpO2, ±3% (50-69% SpO2). PPR Accuracy: ±3 beats per minute.