Datascope Passport XG Features A versatile vital signs monitor specifically designed for surgery, bedside and transport applications. The large, easy-to-read electro luminescent display provides up to three waveforms. The Passport’s easy-to-understand menu and single dedicated function keys make it fast and easy-to-use. Featuring EKG, NIBP, pulse oximetry, respiration, temp and recorder, the Passport can also be configured with optional mainstream end-tidal CO2. Light weight and portable, the Passport is a perfect device for multi-parameter monitoring needs. 3/5 Lead ECGt Printert Non-invasive blood pressuret Pulse oximetryt Battery back up for transport Datascope Passport XG Specifications Display S21.1 cm x 15.8 cm(1.5 kg) ECG Leads I, II, III, aVR, aVL, aVF and V. Defibrillator overload protection: Withstand Lown and trapezoidal or Edmark waveform up to 400 joules applied to 100 ohms load and electrode at 20 second intervals. Recovery time: time for trace to return to screen from defibrillator moo pulse is 3 seconds maximum. IBP Range to digital display; systolic/diastolic mean -20 to +300 mmHg. Accuracy: 2 mmHg or 2%, whichever is greater to numerical display position. Zero range: ±120 mmHg minimum at nominal gain. Heart Rate Range - 30-300 bpm for adult/child, 30-350 bpm for neonatal. Accuracy - 30-250 ±3 bpm or ±3%, whichever is greater. NIBP Technique: oscillometric. Systolic range: 50 to 250 mmHg for adult/ped mode, 15 to 150 mmHg for neonatal mode. Diastolic range: 30 to 200 mmHg for adult/ped mode, 10 to 150 mmHg for neonatal mode. Systolic accurancy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/ped), mean error less than 4 mmHg, standard deviation less than 13 mmHg (neonatal) Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/ped), mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal). • Heart rate meter range: 30-250 bpm. Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater. Temperature TScale: selectable °C or °F. Range: 15°C to 45°C, 59°F to 113°F. Accuracy: ±0.1°C to 45°C or ±0.2°F 59 to 113°F Respiration (ECG) Range: 4-200 pm. Accuracy: ±2% or ± bpm, whichever is greater Recorder Speed - 50, 25, 12., 6.25, 3.125 mm/sec ±5% C02 Range: 0-14.8 vol%, 0-14.8 kPa, 0-11 mmHg, 0-111 Torr. Rise Time: <400ms. Accuracy: ±(0.2% vol% to 2% of reading) 02 Range: 0-100 vol%. Rise time: <400 ms. Accuracy: ±(0.2% vol% + 2% of reading) N02 Range: 0-100% N2O. Rise time: <450 ms. Accuracy: ±(2 vol%+ 2% of reading) Battery Type: 2 sealed lead acid batteries. Voltage: 12 VDC nominal (@2.3A load). Capacity: 2.3 AH each. Run time: 1.5 hours from full charge of new battery at 25°C with SpO2, 1 NIBP every 15 minutes, no recording. Recharge time: 16 hours. Low battery warning: 11.6V, ±3.5%. • Low battery cut off: 11.0V ±2.8%