• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Drager Infinity Gamma XL

Drager Infinity Gamma XL

Brand:   Drager
Condition:   SellerRefubrished
The Infinity® Gamma and Gamma XL configured patient monitors, now with VF5 soft
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Drager Infinity Gamma XL Features The Infinity® Gamma and Gamma XL configured patient monitors, now with VF5 soft- ware functionality, provide a full set of the most commonly used parameters in a compact, user-friendly package. Because of the unique Pick and Go‚® capabilities, these monitors provide continuous surveillance while eliminating the need to purchase separate transport monitors. Patient data from both monitors is available either hardwired or wirelessl over the Infinity Network. Provide monitoring versatility for any sub-acute care setting Display 3 or 4 channels and offer a choice of sizes Provide continuous monitoring and data collection Drager Infinity Gamma XL Specifications Monitoring Capabilities Neonatal, pediatric and adult applications ECG Available leads 3-lead set Leads: I, II, III 5-lead set Leads: I, II, III, aVR, aVL, aVF, V 6-lead set Leads: I, II, III, aVR, aVL, aVF, V, V+ Measuring range 15 to 300 bpm Accuracy ± 5 bpm or ± 2% (whichever is greater) Frequency range (± 3 db) 0.5 Hz to 28 Hz (50 Hz) 0.5 Hz to 40 Hz (60 Hz) Filter Frequency 50 to 60 Hz QRS Detection Range Alarms User-selectable upper and lower limits Pacer detection Leads: I, II, or III Amplitude: ± 5 to ± 700 mV Separation between pulses: 30 msec Width (dp): 0.1 to 2.0 msec Accessories 3-, 5- or 6-lead electrode set Dual Lead ST Analysis Refer to ST datasheet 9049456 Respiration Sensing lead II Measuring method Impedance pneumography Auxiliary current 10μA for any active electrode Detection threshold 0.15 to 4.0 in manual mode (user adjustment) Adult and pediatric: 0.20 to 10.5 in auto mode (automatic adjustment) Neonatal: 0.20 to 1.5 in auto mode (automatic adjustment) Measuring range 0 to 155 breaths/min Accuracy ± 1 l/min or ± 2% (whichever is greater) Alarms User-selectable upper and lower respiration rate Pulse Oximetry (SpO2) Displayed parameters Saturation (fraction of oxyhemoglobin to functional hemoglobin) and pulse (rate and curve) Measuring method Absorption spectrophotometry Pulse 15 to 300 bpm Accuracy SpO2: 0 to 69% not specified SpO2: 70 to 100% ± 2% (except ± 3% when using Nellcor® DS-100A and ± 3.5% when using Masimo® LNOP-Ear) Saturation accuracy increases by ± 1 digit for neonates Pulse: ± 3 bpm or ± 3% (whichever is less) Alarms User-selectable upper and lower limits for SpO2 and pulse Accessories Dräger Medical-approved Masimo and Nellcor sensors Temperature Displayed parameters Absolute temperature Measuring range 0 to 50°C Accuracy Probe: ± 0.1°C System: ± 0.2°C Alarms User-selectable upper and lower limits Accessories Dräger Medical-approved core and skin probes Noninvasive Blood Pressure (NBP) Displayed parameters Systolic, mean and diastolic pressures Measuring method Oscillometric utilizing step deflation Modes of operation Manual (single measurement) interval or continuous (5 minutes) Interval times Off, 2, 2.5, 3, 5 (increments of 5), 30, 45, 60, 120, 180, 240 minutes Measuring range (default) Adult (Adult 270 mmHg) (Adult 180 mmHg) Heart rate 30 to 240 bpm 30 to 240 bpm Systolic 30 to 250 mmHg 30 to 170 mmHg Mean 20 to 230 mmHg 20 to 150 mmHg Diastolic 10 to 210 mmHg 10 to 130 mmHg Pediatric (Pediatric 180 mmHg) (Pediatric 140 mmHg) Heart rate 30 to 240 bpm 30 to 240 bpm Systolic 30 to 170 mmHg 30 to 130 mmHg Mean 20 to 150 mmHg 20 to 110 mmHg Diastolic 10 to 130 mmHg 10 to 130 mmHg Neonatal (Neonatal 140 mmHg) (Neonatal 90 mmHg) Heart rate 30 to 240 bpm 30 to 240 bpm Systolic 30 to 130 mmHg 30 to 80 mmHg Mean 20 to 110 mmHg 20 to 70 mmHg Diastolic 10 to 100 mmHg 10 to 60 mmHg Cuff pressure Default inflation pressure Adult (270): 180 mmHg ± 5 mmHg Pediatric (180): 130 mmHg ± 5 mmHg Neonatal (140): 110 mmHg ± 5 mmHg Adult (180): 130 mmHg ± 5 mmHg Pediatric (140): 110 mmHg ± 5 mmHg Neonatal (90): 80 mmHg ± 5 mmHg Inflation pressure after a valid measurement (± 5 mmHg) Adult (270): Systolic + 25 mmHg Pediatric (180): Systolic + 25 mmHg Neonatal (140): Systolic + 30 mmHg Adult (180): Systolic + 25 mmHg Pediatric (140): Systolic + 30 mmHg Neonatal (90): Systolic + 20 mmHg Maximum inflation pressure Adult (270): 265 mmHg ± 5 mmHg Pediatric (180): 180 mmHg ± 5 mmHg Neonatal (140): 142 mmHg ± 5 mmHg Adult (180): 180 mmHg ± 5 mmHg Pediatric (140): 142 mmHg ± 5 mmHg Neonatal (90): 80 mmHg ± 5 mmHg Minimum inflation pressure Adult (270): 110 mmHg ± 5 mmHg Adult (180): 90 mmHg ± 5 mmHg Pediatric (180): 90 mmHg ± 5 mmHg Pediatric (140): 70 mmHg ± 5 mmHg Neonatal (both): 70 mmHg ± 5 mmHg Connector Quick-release connector with single airway