• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Drager Fabius Tiro

Drager Fabius Tiro

Brand:   Drager
Condition:   SellerRefubrished
Drager Fabius Tiro
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Drager Fabius Tiro Features Provides high-quality ventilation in small spaces. Compact design without having to compromise on features or flexibility. Highly maneuverable cart. Standardized Drager user interface for easy and intuitive operation. All major ventilation modes. High-contrast display. CLIC absorber compatible. Intelligent safety features for enhanced patient protection. Drager Fabius Tiro Specifications Base Uint Dimensions Cart version without COSY: Approx. 22.8 × 53.6 × 24.7 in (57.9 × 136.1 × 62.7 cm) Cart version (incl. COSY): Approx. 30.5 × 53.6 × 33.0 in (77.2 × 136.1 × 83.8 cm) Wall version (incl. mounting bracket and COSY): Approx. 28.4 × 21.9 × 30.5 in (72.1 × 55.6 × 77.5 cm) Weight and Load Fabius Tiro Cart (incl. COSY) without supplementary cylinders and vaporizers: 256 lb (116 kg) Wall mount (incl. mounting bracket): 105.5 lb (47.8 kg) Power and Battery Backup Power input: 100 to 240 VAC, 50/60 Hz, 70 VA Operation time with fully charged batteries: Minimum 45 minutes (up to 120 minutes) Anesthesia Gas Supply Module Range of fresh gas flow indicators: 0.00 to 12.0 l/min Total fresh gas flow meter: 0 to 10 l/min, calibrated with 50% O2 and 50% N2O mixture O2 flush: At 87 psi (6 bar): max. 75 l/min; at 41 psi (2.8 bar): min. 25l/min) Vaporizer mount: Single Dräger or Selectatec®; optional standby vaporizer parking holder Ventilator Operating Specifications General Ventilator E-vent®: Electronically controlled, electrically driven TOperating modes: Standard; Manual/spontaneous, Volume control (VC), Option: pressure control (PC), Option: pressure support (PS), Option: synchronized volume control, Ventilation with PS (SIMV/PS) O2 flush: At 87 psi (6 bar): max. 75 l/min; at 41 psi (2.8 bar): min. 25l/min) Vaporizer mount: Single Dräger or Selectatec®; optional standby vaporizer parking holder Control Input Ranges Breathing frequency (rate): 4 to 60 bpm Positive end expiratory pressure (PEEP): 0 to 20 cm H2O Inspiration/expiration ratio (Ti:Te): 4:1 to 1:4 Pressure limit (Pmax): 15 to 70 cm H2O Tidal volume (Vt): 20 to 1,400 ml in volume control; 20 to 1,100 ml in SIMV/PS Inspiration pause (Tip:Ti): 0 to 50% SIMV inspiratory time: 0.3 to 4.0 sec Inspiratory pressure (Pinsp): PEEP +5 to 65 cm H2O Inspiratory flow (InspFlow): 10 to 75 l/min in volume and pressure control; 10 to 85 l/min in pressure support Pressure support level (PPS): PEEP +3 to 20 cm H2O Min. frequency for apnea ventilation (freq. in min.): 3 to 20 bpm and “OFF” Trigger level: 2 to 15 l/min Integrated safety functions: Sensitive oxygen ratio controller (S-ORC) guarantees a minimum O2 concentration of 23% in an O2/N2O mixture. N2O is cut off if the O2 fresh gas valve is closed or if O2 flow is less than 0.2 l/min. Audible and visual (flashing red LED) indications turn on in the event O2 pressure drops below 20 psi (1.38 bar) ±4 psi (0.27 bar). In the event of electricity and battery failure, manual ventilation, gas delivery, and agent delivery are possible. Positive pressure relief valve opens at 75 ±5 cm H2O. Negative pressure relief valve opens at –8 ±2 cm H2O. Ventilator Monitoring Monitoring: Continuous monitoring of inspiratory O2 concentration, breathing frequency, tidaln volume expiratory, expiration, minute volume, peak airway pressure, PEEP, and selection of mean or plateau pressure. In addition, all fresh gas flow information is displayed as virtual flow tubes. Expiratory minute volume range: 0 to 99 l/min Control screen: 6.5 in (16.5 cm); black/amber (color mode option) Breathing System Volume of entire compact breathing system: 1.7 l plus bag Volume of CO2 absorber: 1.5 l (standard) [option: prefilled Dräger Sorb CLIC absorber with 1.2 l volume] Gas Supply and Connection Gas supply: O2, N2O, and air Cylinder yokes: O2 and N2O pin-indexed hanger yokes Other Communication interface: 1 × RS232 (standard) [additional RS232 optional] Protocols: Vitalink and Medibus Data available for export: All alarms, pressure, O2, volume and fresh gas flow data, ventilations settings, flow curve, and pressure curve Writing surfaces: Pull-out tray (standard) Additional accessories: Anesthetic gas scavenging system (AGSS), endotracheal suction unit, and integrated O2 flow tube