• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Datascope Passport 2 ECG and Multiparameter Monitor

Datascope Passport 2 ECG and Multiparameter Monitor

Brand:   Datascope
Condition:   SellerRefubrished
The Passport 2 features an incredibly intelligent display interface which allows the user to evaluate patient status at a glance.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Datascope Passport 2 Features The Passport 2 features an incredibly intelligent display interface which allows the user to evaluate patient status at a glance. Data is presented clearly, concisely and logically. Waveforms are aligned to digital data for immediate interpretation. Graph and list displays are easily configured to personal preference. The 4 Auto-Set Alarms program is quickly configured and extremely easy to use. Best of all, personalized custom settings retained on the PCMCIA cards assure super fast set-up. Datascope Passport 2 Specifications Dimensions Monitor size: 9.5"H x 11.9"W x 7.4"D (24.1 cm x 30.2cm x 18.8cm) Weight: 14.3 lbs. (6.5 kg) with 2 batteries.; 11.4 lbs. (5.2 kg) without batteries. Battery requirements 2 sealed lead acid batteries, 12 Vdc @ 2.3A load, 2.3 AH each battery. Run time 2 hours +/- 6 minutes from two fully charged batteries at 25°C with ECG SpO2 and 1 NIBP every 15 minutes, no recording, no CO2. Recharge time: 16 hours maximum. Power AC voltage: 100-240 VAC +/-10% 50/60 Hz +/-3 Hz Single Phase. Power consumption: 60-72 watts, 0.6-0.3 Amps. Heart Rate Meter Range: 30-300 bpm adult/ Pediatric, 30-350 bpm Neonate. Accuracy: +/-3bpm or +/-3% at 30-250 bpm whichever is greater, +/-5% at 251-350 bpm. IBP Range: Sys/Dia/Mean: 30- +300 mmHg. Accuracy: +/- 2 mmHg or 2% whichever is greater. Scale: -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg. NIBP Technique: Oscillometric. Connector type: Rectus. Systolic range: adult: 55-235 mmHg, pediatric: 55-160 mmHg, neonate: 45-120 mmHg. Diastolic range: adult: 30-220 mmHg, pediatric: 30-150 mmHg, neonate: 20-100 mmHg. Systolic accuracy: mean error less that +/- 5 mmHg, standard deviation less than +/- 8 mmHg. Diastolic accuracy: mean error less that +/- 5 mmHg, standard deviation less than +/- 8 mmHg. Pulse rate range: adult/pediatric: 35 to 245 bpm, neonate: 70 to 245 bpm. Pulse rate accuracy: +/-3 bpm or 3% whichever is greater. Temperature Scale: Selectable C° or F° Range: 15° to 45° C/ 59° to 113° F Accuracy: +/- 0.1°C (15° C to 45° C); +/- 0.2° F (59° to 113° F) exclusive of probe errors. Respiration Range: 4 to 200 bpm. Accuracy: +/-2% or 2 breaths per minute whichever is greater from 4 to 150 bpm, +/- 4% from 151 to 200 bpm. CO2 (Microstream) Range: 0-99 mmHg. Accuracy: 0-38 mmHg +/-2 mmHg, 39-99 mmHg +/-5% +0.08% for every 1 mmHg above 40 mmHg. Respiration rate: 0-150 bpm. Respiration accuracy: +/- 1 breath per minute from 0-40 bpm, +/-2 bpm from 41-70 bpm, +/-3 bpm from 71-100 bpm, +/-5 bpm from 101-150 bpm. ECG Leads: I, II, III, aVR, aVL, aVF, V. Pulse Oximetry SpO2 saturation accuracy with no motion conditions. Adult / pediatric: 70 to 100% +/-2 digits SpO2, Neonate: 70 to 100% +/-3 digitsSpO2. SpO2 saturation accuracy during motion. Adult / pediatric / neonate: 70-100% +/-3 digits SpO2.