Drager Infinity M300 Features The innovative Drager Infinity M300 patient-worn monitor provides continuous surveillance of telemetry patients using the hospital’s existing Wi-Fi network. The unit’s color screen and audible alarms let you assess and respond to your patient’s status on the spot. The M300 offers a Wi-Fi-based, durable, lightweight patient-worn monitor that provides continuous surveillance to support patient safety. Built-in color screen with waveforms and vital sign values, providing local surveillance to augment monitoring at the Infinity CentralStation. Visible and audible alarms that immediately alert you to changes in the patient’s condition. Integrated Arrhythmia Classification Expert (ACE®) and pacer detection algorithms. Built-in SpO2, eliminating the need for an additional pulse oximetry device or module. Wi-Fi CERTIFIED technology for reliable data transfer on standard wireless networks. Support for WPA2 encryption using 802.11 b/g. Drager Infinity M300 Specifications Dimensions Height: 5.6 In (14.2 cm) Width: 3 In (7.6 cm) Depth: 1.2 In (3.1 cm) Weight: 10.5 oz (295 g) Display Size / Viewing Area: 2.2 In (5.5 cm) diagonal Resolution: 220 x 176 pixels Communications Network: IEEE 802.11b/g/n (2.4 GHz); 802.11a/n (5 GHz) Wireless Encryption: WPA2 – Personal Mode; WPA2 – Enterprise Mode Radio Power Output: (2.4 GHz); 25mW maximum (5 GHz) Battery Power Source: Rechargeable 3.75 V lithium-ion battery Battery Operating Time: ECG only: 17 to 19 hours ECG + Continuous SpO2: 14 to 16 hours Operation time varies according to use of display, alarm alerts, and wireless environment (roaming) ECG Adult / Pediatric 5-wire: I, II, III, aVR, aVL, aVF, V 6-wire: I, II, III, aVR, aVL, aVF, V, V+ 6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV3, dV4, V5, dV6 Detected Events / Rhythms: Asystole, Ventricular Fibrillation, Ventricular Tachycardia, Bradycardia, Ventricular Run, Accelerated Idioventricular Rhythm, Supraventricular Tachycardia, Ventricular Couplet, Ventricular Bigeminy, Tachycardia, Pause, Artifact, PVC/min Pacemaker Detection Leads: I and (II or III) Detection Amplitude: ±2 to ±700 mV Detection Width: 0.1 to 2.0 ms ST Segment Analysis Leads Analyzed: 3-wire: I, II, or III 5-wire: I, II, III, aVR, aVL, aVF, V 6-wire: I, II, III, aVR, aVL, aVF, V, V+ 6-wire with Infinity TruST 12-lead: I, II, III, aVR, aVL, aVF, dV1, V2, dV2, dV3, dV4, V5, dV6 Pulse Oximetry (Optional) Parameter Display: Percentage of functional (oxygen-saturated) hemoglobin (%SpO2); pulse rate Measuring Method: Absorption-spectrophotometry