Biolight BLT V6 Features With the BLT V6 Vital Sign Monitor, lightweight vital sign monitoring has never been easier. The V6 contains a 7” color display for quick viewing of all parameters and easy visibility from a distance. The instant infra-red ear thermometer provides accurate temperature and includes one box of thermometer probe covers. A rechargeable (400ah) lithium-ion battery ensures worry-free transporting with long lasting battery life and compact design. 7” color display Parameters: (NIBP, Sp02, C02, Temp) Recorder Two-trace digital field Hr/PR Sp02 NiBP (systolic, diastolic, & mean) Screen display of alarm limits or disable status Pr range 20 to 250 bpm Sp02 0 - 100% display of plethysmograph Pulse strength & Sp02 valves NiBP range 10 to 270 mm hg accuracy +/- 3mm hg Instant infrared ear thermometer w/ one box thermometer probe covers Alarm setting for all parameters 5000 group NiBP measurement data review Rechargeable lithium-ion battery (4000 ah)r Biolight BLT V6 Specifications Dimensions Size: 160x130x260mm (WxHxD) Weight: (2.5 kg) (Including a lithium battery) Display Size: 7” Color Anti-glare TFT LCD Display Resolution: 234x480 pixels Power Input voltage: AC: 100V-240V, 50Hz/60Hz Input power: 7OVA Fuse: T1.6AU250V, 2-Φ5x20mm Battery Type: 11.1V 4000mAh rechargeable lithium ion battery Operating time: >8 hours Charge time: 6h to 100% (Standby) Data Storage Clinic Mode: Patient quantity: 1000 Recording number: 16000 Single patient clinic record number: 1-16000 Monitor Mode: Patient quantity: 1 Trend data: Resolution 1 Min: Can store 96 hours Resolution 5 Min: Can store 480 hours Resolution 10 Min: Can store 960 hours Alarm events: 1000 NIBP measurement record: 5000 Environmental Operating Temperature: (5~40) ℃ Humidity: ≤85% (noncondensing) Atmospheric Pressure: (860~1060) hPa Transportation and Storage Temperature: (-20~+55) Humidity : ≤93% (noncondensing) Atmospheric Pressure: (500~1060) hPa PR Measurement range: 20~250 bpm Resolution: 1 bpm Accuracy: ±1 % or± 1 bpm, whichever is the greater BLT Digital SpO2 Measurement range (0~100) % Resolution: 1% Accuracy: ± 2% (70%-100%); ± 3% (35%-69% ) Nellcor SpO2 (Option) Measurement range (0~100) % Resolution: 1% Accuracy: ± 2% (70%~100%) (Adult); ± 3% (70%~100%) (Neonate); ± 2% (70%~100%) (Low Perfusion) NIBP Technique: Automaticoscillometry Range: Adult: 10-270mmHg Child: 10-235mmHg Neonate: 10-135mmHg Accuracy: Static ±3 mm Hg Clinic: Average error: ±5 mmHg Standard Deviation: ≤8 mmHg Unit: mmHg.kPa Pulse Rate Range: 40-240 bpm Microstream EtCO2 (Option) Measurement way: Infrared spectrum Measurement mode: sidestream Sample Flow Rate: 50 ml/min± 10 ml/min Measurement Range: (0-19.7) %, (0-150 mmHg) Resolution: 0.1% or 1mmHg Unit: %, mmHg, kPa Accuracy: ±2 mmHg O mmHg to 40 mmHg ±5% of reading 41 mmHg to 70 mmHg ±8% of reading 71 mmHg to 100 mmHg ±10% of reading 101 mmHg to 150 mmHg (760mmHg, temperature is 25 Degrees C) (when RR >80 rpm, all the range is ±12% of reading)