• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Biolight BLT V6

Biolight BLT V6

Brand:  
Condition:   Select
With the BLT V6 Vital Sign Monitor, lightweight vital sign monitoring has never been easier.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Biolight BLT V6 Features With the BLT V6 Vital Sign Monitor, lightweight vital sign monitoring has never been easier. The V6 contains a 7” color display for quick viewing of all parameters and easy visibility from a distance. The instant infra-red ear thermometer provides accurate temperature and includes one box of thermometer probe covers. A rechargeable (400ah) lithium-ion battery ensures worry-free transporting with long lasting battery life and compact design. 7” color display Parameters: (NIBP, Sp02, C02, Temp) Recorder Two-trace digital field Hr/PR Sp02 NiBP (systolic, diastolic, & mean) Screen display of alarm limits or disable status Pr range 20 to 250 bpm Sp02 0 - 100% display of plethysmograph Pulse strength & Sp02 valves NiBP range 10 to 270 mm hg accuracy +/- 3mm hg Instant infrared ear thermometer w/ one box thermometer probe covers Alarm setting for all parameters 5000 group NiBP measurement data review Rechargeable lithium-ion battery (4000 ah)r Biolight BLT V6 Specifications Dimensions Size: 160x130x260mm (WxHxD) Weight: (2.5 kg) (Including a lithium battery) Display Size: 7” Color Anti-glare TFT LCD Display Resolution: 234x480 pixels Power Input voltage: AC: 100V-240V, 50Hz/60Hz Input power: 7OVA Fuse: T1.6AU250V, 2-Φ5x20mm Battery Type: 11.1V 4000mAh rechargeable lithium ion battery Operating time: >8 hours Charge time: 6h to 100% (Standby) Data Storage Clinic Mode: Patient quantity: 1000 Recording number: 16000 Single patient clinic record number: 1-16000 Monitor Mode: Patient quantity: 1 Trend data: Resolution 1 Min: Can store 96 hours Resolution 5 Min: Can store 480 hours Resolution 10 Min: Can store 960 hours Alarm events: 1000 NIBP measurement record: 5000 Environmental Operating Temperature: (5~40) ℃ Humidity: ≤85% (noncondensing) Atmospheric Pressure: (860~1060) hPa Transportation and Storage Temperature: (-20~+55) Humidity : ≤93% (noncondensing) Atmospheric Pressure: (500~1060) hPa PR Measurement range: 20~250 bpm Resolution: 1 bpm Accuracy: ±1 % or± 1 bpm, whichever is the greater BLT Digital SpO2 Measurement range (0~100) % Resolution: 1% Accuracy: ± 2% (70%-100%); ± 3% (35%-69% ) Nellcor SpO2 (Option) Measurement range (0~100) % Resolution: 1% Accuracy: ± 2% (70%~100%) (Adult); ± 3% (70%~100%) (Neonate); ± 2% (70%~100%) (Low Perfusion) NIBP Technique: Automaticoscillometry Range: Adult: 10-270mmHg Child: 10-235mmHg Neonate: 10-135mmHg Accuracy: Static ±3 mm Hg Clinic: Average error: ±5 mmHg Standard Deviation: ≤8 mmHg Unit: mmHg.kPa Pulse Rate Range: 40-240 bpm Microstream EtCO2 (Option) Measurement way: Infrared spectrum Measurement mode: sidestream Sample Flow Rate: 50 ml/min± 10 ml/min Measurement Range: (0-19.7) %, (0-150 mmHg) Resolution: 0.1% or 1mmHg Unit: %, mmHg, kPa Accuracy: ±2 mmHg O mmHg to 40 mmHg ±5% of reading 41 mmHg to 70 mmHg ±8% of reading 71 mmHg to 100 mmHg ±10% of reading 101 mmHg to 150 mmHg (760mmHg, temperature is 25 Degrees C) (when RR >80 rpm, all the range is ±12% of reading)