• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
Medical Device Depot
Welch Allyn Connex Spot Monitor

Welch Allyn Connex Spot Monitor

Brand:   Welch Allyn
Condition:   New
The Connex® Spot Monitor features an easy-to-use, vivid touchscreen display and provides accurate vital signs measurement including blood pressure averaging, spot checking, interval monitoring and custom scoring across patient populations.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Features and Benefits Best-in-class accuracy and performance for neonate through adult patients Blood pressure averaging to help ensure accurate hypertension diagnosis Allows clinician to safely leave room while BP averaging is running Partnerships with more than 90 leading EMRs including Epic and Cerner SureBP technology provides BP in only 15-seconds - 3X faster than competitors Connex Scoring App on-device calculator for custom protocols like NEWS, MEWS Choice of leading SpO2 technologies: Masimo®, Nellcor® or Nonin® Mobile stand option including work surface w/integrated battery for extended usage Connects to select Health O Meter® digital scales. Click here for the Health O Meter Scales Power Supply (7000-PS) is included with the purchase. Materials Included Connex Spot Monitor (1) Adult Blood Pressure Cuff (1) Large Adult Blood Pressure Cuff (1) 5 ft Blood Pressure Tubing (1) Lithium Ion Battery (1) Hospital Grade Cord (1) Power Supply (1) SureTemp or Braun Pro 6000 Thermometer (Optional) (1) Nonin, Nellcor or Masmio SpO2 (Optional) User Manual Note: If you order a mounting option with your Connex Spot Monitor, the power supply is included with the mounting option. See mounting options below: Connex Spot Accessory Power Management Stand (7000-APM) Connex Spot Classic Mobile Stand (7000-MS3) Connex Spot Wall Channel (7000GCX)

Additional Information

The Connex® Spot Monitor features an easy-to-use, vivid touchscreen display and provides accurate vital signs measurement including blood pressure averaging, spot checking, interval monitoring and custom scoring across patient populations. The device connects wirelessly to your EMR and accurately sends vitals to the patient chart from the point of care to help improve efficiency. It offers an upgradeable design and custom configurations including a choice of thermometry and/or pulse oximetry, connectivity and mounting/mobility options. In addition, the new Accessory Power Management Stand with WhisperDrive™ technology features additional power backup, providing up to 17 hours of on-time, alleviating the need to charge the monitor as frequently.

Tech Specs

Technical Specifications Physical Specifications Characteristics Electrical rating: 100 – 240 V AC, 50 – 60 Hz, 0.8X– 1.5 A Duty cycle: Continuous operation Type of protection against electric shock: Class I internally powered Degree of protection against electric shock, for parts applied to patients Type BF defibrillator proof IEC EN 60601-1, 2nd and 3rd Editions Recovery time following defibrillator discharge: Less than or equal to 10 seconds Dimensions Height Standard: 6.3 in. (16.1 cm ) Extended: 6.5 in. (16.6 cm ) with Braun 6000 Extended: 6.4 in. (16.6 cm ) with SureTemp Width Standard: 9.2 in. (23.4 cm ) Extended: 11.7 in. (29.8 cm ) with Braun 6000 Extended 11.7 in. (29.8 cm ) with SureTemp Depth Standard: 2.3 in. (5.8 cm ) Extended: 4.4 in. (11.0 cm ) with Braun 6000 Extended: 4.2 in. (10.6 cm ) with SureTemp Weight Standard: 2.9 lb (1.3 kg ) Extended: 3.7 lb (1.7 kg ) with Braun 6000 Extended: 3.5 lb in. (1.6 kg ) with SureTemp Graphic Display Resolution Dimensional Outline Width: 6.5 in. (103.8 mm) Height: 4.1 in. (164.9 mm) Depth: 0.13 in. (3.40 mm) Active Area Width: 6.1 in. (154.08 mm) Height: 3.4 in. (85.92 mm) Resolution: 800 x 480 pixels Pixel arrangement: RGB (red, green, blue) Pixel Size: 63.2 μm (W) x 179 μm (H) Luminance: 530 cd/m2 Speaker Volume Luminance: 530 cd/m2 Alarm and Pulse Tones Pulse frequency: 150 – 1000 Hz Number of harmonic components in the range 300 Hz to 4000 Hz: Minimum of 4 Effective pulse duration: High Priority: 75 –200 ms Medium and Low Priority: 125 – 250 ms Rise Time: 10 10 – 20% of rise time Battery Specifications 2 Cell Battery Specifications Continuous run time (Nellcor): 5.22 hours of use 6 patients/hour - 41 patient cycles (Nellcor): 6.83 hours of use 8 patients/hour - 54 patient cycles (Nellcor): 6.78 hours of use 8 patients/hour - 55 patient cycles (Nonin): 6.90 hours of use Acute care continuous 10 minute cycles - 49 patient cycles - BP, temp, SpO2, no radio, no scanner (Nellcor): 8.22 hours of use Acute care continuous 10 minute cycles - 50 patient cycles - BP, temp, SpO2, no radio, no scanner (Nonin): 8.37 hours of use Acute care continuous 10 minute cycles - 49 patient cycles - BP, temp, SpO2, no radio, no scanner (Masimo): 8.29 hours of use Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Nellcor): 6.84 hours of use Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Nonin): 6.96 hours of use Acute care continuous 10 minute cycles - 41 patient cycles - BP, temp, SpO2, radio, scanner (Masimo): 6.90 hours of use Nurse Call Nurse Call: 25 V AC or 60 V DC maximum at 1A maximum NIBP specifications Cuff pressure range: Meets or exceeds IEC/ISO 80601-2-30 standards for cuff pressure range Systolic range Adult: 30 to 260 mmHg Pediatric: 30 to 260 mmHg Neonate: 20 to 120 mmHg Diastolic range Adult: 20 to 220 mmHg Pediatric: 20 to 220 mmHg Neonate: 10 to 110 mmHg Cuff Inflation Target Adult:160 mmHg Pediatric: 140 mmHg Neonate: 90 mmHg Maximum Target Pressure Adult: 280 mmHg Pediatric: 280 mmHg Neonate: 130 mmHg Blood pressure determination time Typical: 15 seconds Maximum: 150 seconds Blood pressure accuracy Meets or exceeds ANSI.AAMI SP10:2002 standards for noninvasive blood pressure accuracy (±5 mmHg mean error, 8 mmHg standard deviation) Mean Arterial Pressure (MAP) range (The formula used to calculate MAP yields an approximate value Adult: 23 to 230 mmHg Pediatric: 23 to 230 mmHg Neonate: 13 to 110 mmHg Pulse rate range (Using blood pressure determination) Adult: 30 to 200 bpm Pediatric: 30 to 200 bpm Neonate: 35 to 220 bpm Pulse rate accuracy (Using blood pressure determination): ±5.0% (±3 bpm) Overpressure cutoff Adult: 300 mmHg ±15 mmHg Pediatric: 300 mmHg ±15 mmHg Neonate: 150 mmHg maximum Temperature Specifications SureTemp Plus Temperature Module Specifications Temperature Range: 80°F to 110°F (26.7°C to 43.3°C) Calibration Accuracy: ±0.2°F (±0.1°C) (Direct mode) Braun ThermoScan Pro 6000 Specifications Temperature Range: 68°F to 108°F (20°C to 42.2°C) Calibration Accuracy: ±0.4°F (±0.2°C) for temperatures ranging from 95.9°F to 107.6°F (35.5°C to 42°C) ±0.5°F (±0.25°C) for temperatures outside of this range Display Resolution: 0.1°F or °C SpO2 Specifications Pulse Rate: 25 to 240 beats per minute (bpm) ± 3 digits (no motion) Detected pulse rate: 20 to 250 beats per minute (bpm) ± 3 digits Nonin Sensor Accuracy Guide SpO2 accuracy testing is conducted during induced hypoxia studies on healthy, non-smoking, light-todark-skinned subjects during motion and no-motion conditions in an independent research laboratory The measured arterial hemoglobin saturation value (SpO2) of the sensors is compared to arterial hemoglobin oxygen (SaO2) value, determined from blood samples with a laboratory co-oximeter. The accuracy of the sensors in comparison to the cooximeter samples measured over the SpO2 range of 70 – 100%. Accuracy data is calculated using the root-mean-squared for all subjects, per ISO 9919:2005, Standard Specification for Pulse Oximeters for Accuracy. Perfusion 40–240 BPM. Adult/Ped +/- 3 digits; Neonate +/- 3 digits Pulse Rate 18 to 321 beats per minute (bpm) No motion (18 to 300 bpm): ± 3 digits Motion (40 to 240 bpm): ± 5 digits Saturation Adult/Pediatrics Percentage: 70% to 100% No Motion Finger Clip: ± 2 digits Flex: ± 3 digits Soft Sensor: ± 2 digits 8000R: ± 3 digits 8000 Q: ± 4digits Motion Finger Clip: ± 2 digits Flex: ± 3 digits Soft Sensor: ± 3 digits Low Perfusion All Sensors: ± 2 digits Neonates Percentage No Motion Finger Clip: ± 3 digits Flex: ± 3 digits Soft Sensor: N/A 8000R: N/A 8000 Q: N/A Motion Finger Clip: ± 3 digits Flex: ± 4 digits Soft Sensor: ± 4 digits Low Perfusion All Sensors: ± 3 digits Environmental Specifications Operating Temperature: 50°F to 104°F (10°C to 40°C) Storage Temperature: -4°F to 122°F (-20°C to 50°C) Operating Altitude: -1250 to 10,000 ft. (-381 m to 3,048 m) Operating Humidity: 15% to 90% Non-condensing Storage Humidity: 15% to 95% Non-condensing Monitor Radio Wireless Network Interface: IEEE 802.11 a/b/g/n Frequency 2.4 GHz frequency bands: 2.4 GHz to 2.483 GHz 5 GHz frequency bands: 5.15 GHz to 5.35 GHz, 5.725 GHz to 5.825Ghz Channels 2.4 GHz: Up to 14 (3 non-overlapping); country-dependent 5 GHz: Up to 23 non overlapping; country-dependent Antenna: Ethertronics WLAN_1000146 Authentication/Encryption Wireless Equivalent Privacy (WEP, RC4 Algorithm) Wi-Fi Protected Access (WPA) EEE 802.11i (WPA2) TKIP, RC4 Algorithm AES, Rijndael Algorithm Encryption Key Provisioning Static (40- bit and 128-bit lengths) PSK Dynamic EAP-FAST EAP-TLS EAP-TTLS PEAP-GTC 1 PEAPMSCHAPv2 PEAP-TLS Antenna: Ethertronics WLAN_1000146 Wireless Data Rates 802.11a (OFDM): 6, 9, 12, 18, 24, 36, 48, 54 Mbps 802.11b (DSSS, CCK): 1, 2, 5.5, 11 Mbps 802.11g (OFDM): 6, 9, 12, 18, 24, 36, 48, 54 Mbps 802.11n (OFDM,HT20,MCS 0-7): 6.5,13,19.5, 26, 39,52, 58.5, 72.2 Mbps Agency Approvals US: FCC Part 15.247 Subpart C, FCC Part 15.407 Subpart E Europe: EN 300 328 (EDR) (v1.8.1), EN 300 328 (LE) (v1.8.1), EN 301 489-1 (v1.9.2), EN 301 489-17 (v2.2.1), EN 301 489-17 (v2.2.1), EN 62311:2008, EN 60950-1 Canada: (IC) RSS-210 standard. IC 3147A-WB45NBT based on FCC testing Singapore: Complies with IDS standard Protocols: UDP, DHCP, TCP/IP Data Transfer Protocols: UDP/TCP/IP Output Power: 39.81mW typical, country-dependent Ancillary IEEE standards: 802.11d, 802.11e, 802.11h, 802.11i, 802.1X Bluetooth Module Wireless Specification Bluetooth: 2.1 + EDR Frequency: 2.402 - 2.480 GHz Maximum Transmit Power: Class 1 +8 dBm from antenna Receive Sensitivity: -89 dBm Range Circa: 100 meters Data Rates: Up to 3 Mbps (over the air) Host Interface USB: Full speed USB 2.0 GPIO: Four configurable lines (1.8V/3.3V configurable by VDD_PADS Operational Modes HCI: Host Controller Interface over USB HID Proxy Mode: Human Interface Device EEPROM 2-wire 64K bits Coexistence 802.11 (WiFi): Three wire CSR schemes supported (Unity-3, Unity-3e, and Unity+) Supply Voltage: Supply 5V ± 10% Power consumption: Current Idle mode ~5 mA File transfer ~58 mA Atennna Option Internal: Multilayer ceramic antenna with up to 41% efficiency Physical Dimensions 8.5 × 13 × 1.6 mm (BT800 module) 16 × 43 × 11 (BT820 USB dongle) Environmental Operating: -30 °C to 85 °C Storage: -40 °C to 85 °C Miscellaneous: Lead free Lead-free and RoHS compliant Approvals Bluetooth: Controller subsystem approved FCC / IC / CE: All BT800 series

Shipping Information

Contact Request

Warranty & Returns

2-Year Warranty