Medfusion 2010 Infusion Pump

Medfusion 2010 Infusion Pump

Brand:   Medfusion
Condition:   SellerRefubrished
Ambulatory syringe pumps that run on either AC current or rechargeable internal batteries. Accepts a broad range of syringe brands and sizes and it has automatic sensing of syringe size.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Medfusion 2010 Features Ambulatory syringe pumps that run on either AC current or rechargeable internal batteries. Accepts a broad range of syringe brands and sizes and it has automatic sensing of syringe size. Ambulatory syringe pumps that run on either AC current or rechargeable internal batteries Accepts a broad range of syringe brands and sizes and it has automatic sensing of syringe size Flow/Rate Range: 0.1-379.0 ML/HR Dependent on Syringe Size Selected Accuracy: Plus or Minus 3% Power Requirements: AC Adapter or internal battery 4.5 in x 3 in x 7.5 in Syringe Size 1-60 ml Alarms: Near Empty, Empty, Volume Limit, Occlusion, Systems Malfunction, Low Battery, Depleted Battery, Syringe Not Loaded,Check Clutch, Invalid Syringe Size. Additional alarms on 2010 & 2010i models: Invalid Number, Alarm Audio Volume, Soft/Loud, Syringe Out and Load Syringe Plunger Medfusion 2010 Specifications Flow Rate 0.1 - 378.0 ml/hr., depending on syringe size selected Volume Limit 00.1 to max. capacity of syringe in increments of 0.1 ml Volume Delivered (2001) - 000.00 to 999.99 in increments of 0.01 ml (2010) - 0000.0000 to 9999.9999 mg or 0000.00 to 9999.99 ml Bolus Rate (2010 only) - Up to 378.0 ml/hr KVO 0.1 - 9.9 ml/hr in increments of 0.1 ml Occlusion Normal: max. 16.4 PSI with Mono 35cc syringe Low: max. 5.96 PSI with Mono 35cc syringe Middle: max. 13.8 PSI with Mono 35cc syringe High: max. 15.0 PSI with Mono 35cc syringe Accuracy ± 3 %, excluding variations in syringe accuracies Battery Capacity 16-hour charge operates the pump for approx. 10 hours at 5.0 ml/hr with a 60-ml syringe Recharge Time 16 hours maximum

Additional Information

General Information About IV Therapy IV Therapy IV therapy is used to deliver by infusion, fluids, medication, or nutrients to patients. There are two main types of administration of infusion, volumetric and syringe/PCA. IV Therapy-Volumetric These pumps are used when the accuracy of fluid volume to be infused is critical such as in the case of medications used for infusion of drugs for circulatory support. Volumetric pumps deliver a given volume of fluid per unit time measured in mL/hour. Volumetric pumps can be single or multi channel. Both types allow for the administration of more than one fluid at a time. Single channel employs a piggyback method while multi-channel uses separate tubing set up for the administration of multiple medications or fluids IV Therapy-Syringe Syringe pumps are used to administer small volumes of fluids or medications. (1 mL to 60 mL syringe) Syringe pumps are an effective way to deliver medication with precision while reducing the chance of human error if the medication were to be administered by a member of the medical staff* (of course human error can occur when inputting data or choosing dose rate over time) Like volumetric pumps, syringe pumps can be programmed to deliver the medication over a predetermined time