Impact Univent 754 Portable Ventilator

Impact Univent 754 Portable Ventilator

Brand:   Impact
Condition:   SellerRefubrished
The Impact Univent Eagle 754 is completely self-contained and requires no outside gas.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Impact Uni-Vent 754 Features The Impact Univent Eagle 754 is completely self-contained and requires no outside gas. Featuring an internal compressor and blender, it offers PEEP with controlled assist, SIMV, Intubated CPAP, and CMV (for apnea backup) ventilation modes. Bright graphic LCD provides monitoring and alarm settings. An interactive demo/teaching mode assures fast start up sequence in as little as three steps. EMI/RFI and Air Medical certified. Limited availability. Unlike anything you have ever seen before, the Eagle is an engineering marvel that adds to the Uni-Vent list of accomplishments. Imagine a self-contained ventilator-compressor-blender weighing just over 12-pounds, with graphics display, powerful monitors and alarms, an interactive demo/teaching mode, and fast startup sequence that allows you to begin operation in as few as 3-steps. Compact and Light weight Operating Modes: ACV, SIMV, CPA and CMV Impact Uni-Vent 754 Specifications Operating Modes ACV – with/without PEEP, SIGH, and PRESSURE PLATEAU SIMV - with/without PEEP SIGH and PRESSURE PLATEAU CPAP – with/without PEEP CMV – for Apnea backup of ACV, SIMV and CPAP General Deliverable Gas(es) Air (Internal Compressor, External 50-PSI); Oxygen (External 50-PSI) Tidal Volume Range 0 to 3000 mL I:E Ratio 1:1 Preset, Adjustable 1:1 to 1:599 Sensitivity Default, 1.5 to 2.0 cmH2O; Adjustable, 1.0 to 6.0 cmH2O Flow Rate Adjustable, 0 to approximately 60 LPM (0 to approximately 1000 ml/sec) Ventilation Rate Adjustable, 1 to 150 bpm, in 1bpm increments (±1 digit on the display panel) Inspiration Time Adjustable, 0.1 to 3 sec, in 0.1 sec increments (±1 digit on the display panel); 1:2 I:E RATION preset FiO2 Adjustable, 21% to 100% (Internal Air/Oxygen Mixer), resolution in 1% increments, accurate to within ±10% Low Pressure Alarm Adjustable, 0 to 50 cmH2O, in 1 cmH2O increments (±1 digit on the display panel) High Pressure Alarm Adjustable, 15 to 100 cmH2O, in 1 cmH2O increments (±1 digit on the display panel) Peek Inspiratory Pressure Relief Adjustable, 15 to 100 cmH2O, in 1 cmH2O increments (±1 digit on the display panel) Pressure Plateau Range, 5 to 90 cmH2O (referenced to HIGH PRESSURE ALARM set-point) Assist/SIMV Sensitivity Default, 1.5 to 2.0cmH2Obellow end pressure PEEP Program range 1 to 20 cmH2O, in 1 cmH2O increments (±1 digit on the display panel) Sigh Occurs once every 100-ventilations or 7-minutes, whichever occurs first. Sigh duration = 150% Vt (truncated to a combined maximum of 3 seconds) Liquid Crystal Display External Air, Sigh, PEEP, Pressure Plateau, High-Pressure Alarm Setting, Low-Pressure Alarm Setting, Ventilation Rate, Inspiration time/I:E Ratio, Tidal Volume, Air/Oxygen Mixer, Mode, Inspiration/Exhalation, Power, Pear Airway Pressure, Mean Airway Pressure, Digital Bar Graph, High/Low, Airway Pressure Alarm Setpoint Indicators, Paw. LED Indicators Charge/Alarm/System Failure LED Digital Bar Graph Range -10 to 100 cmH2O LCD Alarm Display Battery Low, External Power Low, Low Pressure, O2 Low/Fail, Disconnect, High Pressure, Apnea, Vt, High PEEP, Ext Air Low/Fail, FIO2, Inverse I/E, Comp, Pressure Alarm Settings, Transducer Calibration, Transducer Calibration Abort, System Failure, Ventilator Fail, Inspiration Time Truncated to 3-seconds, Plateau Volume, Preventative Maintenance Due, Vt Settings, Extended Non-Use/ Storage, External Power Failure

Additional Information

General Information About Ventilators Mechanical Ventilation Use of a machine to induce alternating inflation and deflation of the lungs with air Regulates Oxygen/CO2 levels in blood Volume and Pressure of Air forced into Lungs is controlled Has to meet varying demands of patient ventilation Modes of Ventilation Volume control Pressure control CPAP/BIPAP Support Ventilation Combination Of Modes Intermittent mandatory Ventilation Components of Ventilator System Compressed Gas Source Patient Breathing Circuit Mixer/Blender Hoses Optional monitoring O2 Volume Classification Driving Mechanism Pneumatic (Mark 7) Electronic (Siemens 900C)Function Respirators: Short time ventilator support Conventional Ventilators :long term, advance Support Portability Transport/battery backup Patients Adult Pediatric Or Neonatal Technologies and Jargon Turbine technology High frequency Oscillatory ventilation Modes IMV, SIMV, PC, VC, S/T etc. MRI Compatible (Non ferromagnetic components) Flow Sensors- Volume Measurements Pressure transducers