• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
GE Optima XR220amx

GE Optima XR220amx

Brand:   GE
Condition:   SellerRefubrished
The Optima XR220amx is a self-contained battery operated mobile radiographic digital X-Ray imaging system designed for performing radiographic exams at the point of care when it is not safe or practical to move the patient to the radiographic room.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

GE Optima XR220amx Features The Optima XR220amx is a self-contained battery operated mobile radiographic digital X-Ray imaging system designed for performing radiographic exams at the point of care when it is not safe or practical to move the patient to the radiographic room. Optima XR220amx is suited for routine radiographic procedures within a hospital including radiology departments, intensive care units, cardiac care units, emergency departments, operating rooms, orthopedics, pediatrics, hospital rooms and clinics. FlashPad Lightweight detector designed for mobile use, weighs less than 4.5 kg (10 lbs.) including battery “Stand-by” mode eliminates boot up cycles and allows exposure within 25 seconds Designed for 24/7 availability. Use with battery or make and process exposures while the unit is charging Detector can support up to 160 Kg (352 lbs.) of distributed load for bariatric applications Detector battery charges automatically while the detector is in the bin Automatic charging algorithms allow the system to be re-charged even if batteries are not fully drained 15kW (nominal) generator and available 30kW(nominal) option GE Optima XR220amx Specifications Wireless Digital Detector Detector battery can take up to 50 exposures per hour and provide enough power for 3 hours of use on a single charge Single panel (non-tiled) amorphous silicon detector with a Cesium Iodide scintillator Image area: 40.4 cm x 40.4 cm (15.9 in x15.9 in) Active matrix: 2024 x 2024 pixels Pixel Pitch: 200 microns Typical upper dynamic range: 7.8mR Typical DQE: @ 0lp/mm: 68%) Two handgrips Detector Environmental Conditions Temperature Operating: 15°C to 35°C Non-Operating: -0°C to 50°C (maximum change 20°C per hour) Humidity Operating: 10% to 80% RH, noncondensing(max. change 30% per hour) Non-Operating: 10% to 95% RH, noncondensing (max. change 30% per hour) Power Capable of 100-240 V nominal, 50/60 Hz operation System battery status display X-Ray Source Nominal Tube Voltage (Radiographic) 40 ~ 150 kV Nominal Focal Spot size (IEC 60336): Large Focus: 1.2 mm Small Focus: 0.6 mm Anode Rotation Speed (minimal): 3200 min-1 Permanent Filtration: 0.9 mm Al/75 kV IEC60522: 1999 Maximum X-ray Tube Current Large Focus: 500 mA Small Focus: 200 mA Maximum Continuous Heat Dissipation: Without Air-circulator: 170 W (238 HU/s) Maximum anode heat units: 140 kHU Exposure time: 4.0 msec – 6.0 sec