• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
GE Datex Ohmeda TEC 7 Sevoflurane

GE Datex Ohmeda TEC 7 Sevoflurane

Brand:   GE /Datex Ohmeda
Condition:   SellerRefubrished
The GE Datex Ohmeda Tec 7 ISevoflurane Anesthesia Vaporizer delivers isoflurane effectively and efficiently.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

GE Datex Ohmeda TEC 7 Sevoflurane Features The GE Datex Ohmeda Tec 7 ISevoflurane Anesthesia Vaporizer delivers isoflurane effectively and efficiently. Each agent specific Tec 7 incorporates significant performance, convenience and ergonomic benefits with important safety features to help improve agent delivery and reliability while reducing overall operating costs. This vaporizer provides output consistency with the dial setting throughout the clinical flow range. Two filling options: Easy-Fil and Funnel Fill. The Easy-Fil filler is designed to simplify agent filling and help minimize agent leaks while filling. Large diameter control dial which incorporates fine graduations of 0.2% between 0 and 1%, and 0.5% from 1 to 8%. Ergonomic agent dial release on the Tec 7 vaporizer allows either left or right-hand operation. GE Tec 7 Isoflurane Vaporizer Specifications Dimensions Height: 9.9 In (25 cm) Width: 4.5 In (11.4 cm) Depth: 8.3 In (21 cm) Weight (Dry): 22 lbs. (7 kg) Agent Capacity Charged: 225 mL of free volitile anesthetic agent. Charging: 300 mL (nominal) to charge dry vaporizers. Retention: 75 mL (nominal) retained by wick system. Pneumatics Calibration: The dials of the Tec 7 Vaporizers for enflurane, isoflurane and halothane are calibrated to 5% v/v in steps of 0.2% up to 1%, and in steps of 0.5% from 1% to 5% at 21°C using O2 at 5 L/min as the carrier gas. Calibration of Sevoflurane The dial of the Tec 7 Vaporizer for sevoflurane is calibrated to 8% v/v Dial is marked in steps of 0.2% up to 1% v/v, and in steps of 1% between 1% and 8% Resistance to Gas Flow “OFF”: Isolated, no resistance from vaporizer “ON”: 5 L/min O2: 10 to 15 cm H2O at 21°C ±2°C Accuracy 5 L/min O2 @ 21°C ± 2°C: Vaporizer 5%: ±0.25% of delivered agent or ±15% of dial setting (whichever is greater) Vaporizer 8%: ±0.4% of delivered agent or ±15% of dial setting (whichever is greater) Flowrate: Vaporizers are designed to provide consistent output throughout the clinical flow range from 200 mL/min to 15 L/min. Operating Conditions Temperature: 18° to 35°C/64° to 95°F Humidity: 30% to 75% relative humidity (non-condensing)