• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Criticare eQuality 506DN

Criticare eQuality 506DN

Brand:   Criticare
Condition:   SellerRefubrished
Criticare’s eQuality™ 506DN is the monitor for everyone. An affordable monitor with features for both spot check and continuous monitoring.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Criticare eQuality 506DN Features Criticare’s eQuality™ 506DN is the monitor for everyone. An affordable monitor with features for both spot check and continuous monitoring. The 506DN patient monitor with sturdy carry-handle attaches quickly to a rolling stand. It can operate on battery power or directly from AC power. It is lightweight and designed for ease of use as a mobile monitor. With a compact design, the 506DN patient monitor adapts readily to hospital, clinic and transport requirements. Proprietary ComfortCuff NIBP measures on inflation for faster, more comfortable readings. Criticare’s DOX digital SpO2 technology with waveform display. Audible and visual alarms are adjustable for use in continuous monitoring. Large responsive keys for fast spot checking with an easy to clean membrane keypad. On-screen menu selection for ease of setup and use. Adult. pediatric and neonate settings for a complete range of patients. Nurse call and connectivity to network systems. Trend last 24 blood pressure measurements with heart rate and SpO2. Direct main (AC) power so no adapter is required. Criticare eQuality 506DN Specifications Physical Properties Mechanical Weight: 4.5 lbs; 2 kg Size: 8 in (H) x 5.5 in (W) x 5.75 in (D); 20.3 cm (H) x 14 cm (W) x 14.6 cm (D) Non-Invasive Blood Pressure Technique: Oscillometric measure upon inflation Measurement Time: <40 seconds typical; 0 to 300mm Hg; standard adult cuff Automatic Measurement Cycles: 1 - 60 minute; 2 - 4 hour; STAT Inflation Pressure Range: 30 to 300mmHg (Adult) 30 to 150mmHg (Pediatric) 20 to 150mmHg (Neonate) Resolution: 1mmHg Clinical Accuracy: SP-10:2002 Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range STAT mode: 5 minutes of consecutive readings Pulse Oximetry Range: 1% to 99% Resolution: 1% Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified Method: Dual wavelength LED Audio: Tone with each detected pulse; pitch varies with saturation Heart (Pulse) Rate Range: 20 to 300bpm Accuracy: Greater of ±1bpm or ±1%, of reading Unspecified for <30 or >240 bpm Resolution: 1bpm Pulse Volume: 10 levels or Off Alarms Indication: Audible; Visual Volume: 10 levels or Off Silence: Yes; 2 minutes or permanent Trend Memory Memory: Last 24 NIBP measurements Parameters: Systolic, Diastolic, MAP, Pulse Rate (records SpO2 pulse rate, and SpO2 saturation if oximetry is monitored) Displays Type: Monochrome LCD Parameters: NIBP, SpO2, pulse rate plethysmograph Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size Languages: English and Spanish System Output Nurse Call: Contact switch; 3.5 mm phone jack Com Port: Serial, RS 232-compatible Settings: External printer or CUSP Power Requirements Voltage: 100 to 240 VAC, 50 to 60 Hz Battery: Rechargeable Battery Life: 8 hours typical Recharge Time: 6 hours Environmental Operating Temperature: 32º to 104º F; 0º to 40º C Storage Temperature: –4º to 149º F; -–20º to 65º C Operating Humidity: 5% to 95%, non-condensing Classification Type of Protection: Class I equipment Degree of Protection: Type CF defibrillator-proof equipment Protection against Ingress: IPX1 rating, Drip-Proof Equipment