• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
SOMA Technology
Baxter AS50 Digital Syringe Pump

Baxter AS50 Digital Syringe Pump

Brand:   Baxter
Condition:   SellerRefubrished
Digital syringe pump.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

More Baxter AS50 Pictures Baxter AS50 - Soma Technology, Inc.Baxter AS50 Pump - Soma Technology, Inc.Baxter AS50 Infusion Pump - Soma Technology, Inc. Baxter AS50 Features: Digital syringe pump. Provides accurate infusion of intravenous solutions, drug solutions, whole blood, and packed blood cells. Indicated for the following routes of administration: intravenous, intra-arterial, epidural or subcutaneous. Accepts standard disposable syringes from 1mL to 60 mL. Baxter AS50 Syringe Pump Specifications: Size: 3.4" x 2.6 x 10" (8.6 x 6.7 x 25 cm) Weight: 3.2 lbs. (1.45 kg) Flow Rate Accuracy ± 3% of full scale plunger travel. (not including syringe tolerance.) Volume Accuracy ± 3%, or 0.007" of travel, whichever is greater. (not including syringe tolerance.) Syringes B-D: 1, 3, 5, 10, 20, 30, 60 mL plastic Sherwood Monoject: 1, 3, 6, 12, 20, 35, 60 mL Terumo: 1, 3, 5, 10, 20, 30, 60 mL Flow Rate Range 0.01 mL/hr to 438 mL/hr, depending on the syringe. Delivery Volume Full syringe volume for 1-60 mL syringes. Data Display Self-prompting, multi-field. Status Display Nine-LED array. Power Requirements AC: 105-125V 60 Hz (battery charger) DC: internal rechargeable battery pack. Battery Operating Time 5 hours of operation at 100 mL/hr. 12 hours of operation at 2 mL/hr using a 60 mL syringe, following a charge of not less than 16 hours.

Additional Information

General Information About IV Therapy IV Therapy IV therapy is used to deliver by infusion, fluids, medication, or nutrients to patients. There are two main types of administration of infusion, volumetric and syringe/PCA. IV Therapy-Volumetric These pumps are used when the accuracy of fluid volume to be infused is critical such as in the case of medications used for infusion of drugs for circulatory support. Volumetric pumps deliver a given volume of fluid per unit time measured in mL/hour. Volumetric pumps can be single or multi channel. Both types allow for the administration of more than one fluid at a time. Single channel employs a piggyback method while multi-channel uses separate tubing set up for the administration of multiple medications or fluids. IV Therapy-Syringe Syringe pumps are used to administer small volumes of fluids or medications. (1 mL to 60 mL syringe) Syringe pumps are an effective way to deliver medication with precision while reducing the chance of human error if the medication were to be administered by a member of the medical staff.* (of course human error can occur when inputting data or choosing dose rate over time.) Like volumetric pumps, syringe pumps can be programmed to deliver the medication over a predetermined time.