Used Topcon 3D OCT-2000 w/Digital Non-Myd Retinal Camera The Topcon 3D OCT-2000 System is the first Spectral Domain OCT system to incorporate a high resolution fundus camera and a userfriendly color touch screen display in a compact, space saving design. What makes the Topcon 3D OCT-2000 unique: » Integrated, high resolution (12.3MP) fundus camera » FastMap™ software enables dynamic viewing of 2D, 3D and fundus images simultaneously » Embedded touch-screen for quick and easy navigation » Historic patient data from Stratus® OCT can be easily imported, analyzed and viewed » Seamless integration with EyeRoute® Image Management System 3D OCT Image Topcon’s proprietary FastMap software pioneered the 3D visualization of OCT data, providing another dimension of clinical information, thereby enhancing the understanding and illustration of complex pathologies such as vitreous traction, macular edema and retina schesis. » 3D visualization of OCT data » Illustrates complex pathologies » Quickly export images and 3D movies for presentations Fundus Image High resolution, non-mydriatic, color fundus images allow for visualization of conditions which otherwise would go undetected with OCT technology, such as disc hemorrhages. The 45 degree field of view and the availability of stereo photos provides the ultimate diagnostic insight. » High resolution 12.3 MP color fundus camera » Easily capture and view stereo photos » PinPoint Registration™ of OCT data in the fundus image B-scan Image FastMap software encompasses the latest in noise reduction algorithms and overlapping scanning technology to create exquisite B-Scan images, which are available almost instantaneously. This greatly reduces chair time for the patient and enhances offi ce workfl ow. » Uses latest in noise reduction algorithms » Enhances office workflow » Customize capture protocols Comprehensive Capturing Capture images of the fovea and optic nerve head in one single scan and high resolution images of the choroid with automatic choroid reference mode. Video Functions Use single touch control to review and playback images and create 2D and 3D videos. Extended Scanning Depth Capture high-quality images of high-myopic and hyperopic patients with a diopter compensation lens and an extended scanning depth of 2.3 mm. Compare Function Allows you to visualize serial exams or view both eyes side by side. FastMap Software Topcon’s proprietary FastMap software ensures consistent, high quality images. Using enhanced 3D registration technology, FastMap reduces artifacts which may be caused by eye movement. This in turn allows for speedy PinPoint Registration of the OCT data within the fundus image without sacrifi cing workfl ow and preserves image quality of the vitreo-retinal interface. In addition, FastMap provides dynamic, simultaneous viewing of the fundus image, and 2D and 3D OCT data, and automatically detects ILM, RFNL, IS/OS junction, RPE and Bruch’s membrane, which can also be modified. Thickness Measurement Functions FastMap software incorporates the latest layer detection algorithms, allowing you to automatically measure total retinal thickness, RNFL or compare against your legacy Stratus measurements. Manual adjustment of all measurement grids combined with auto and manual registration of serial exams gives you the highest level of confi dence in retinal and RFNL thickness measurements. Mosaic Function Create panoramic views from the macula to the optic disc.

Tech Specs

Field Angle 45° Working Distance 40.7mm Pupil Diameter ≥ 3.3 mm for Fundus image Scanning Range 8.2 x 3.0 mm, 6.0 x 6.0 mm, 4.5 x 4.5 mm or 3.0 x 3.0 mm A Scan Speed 27,000 A Scans/sec. Scan Depth 2.3mm Horizontal Resolution 20μm Longitudinal Resolution 5-6μm Fundus Observation Near IR Fundus Camera Nikon D90 12.3 MP Color Fixation Adjustable internal matrix LCD and external fi xation device Diopter Scale Range -13D to +12D (in fundus photography) Light Source Super luminescence diode (SLD) Wavelength 840nm Half Bandwidth: 50nm Output on cornea ≤ 0.65 mW Automatic OCT Reference Focus Vitreous and Choroid Scan Patterns 3D, Cross*, Raster*, Line*, Radial*, Circle* (*available with oversampling, overlapping) Power Supply Source voltage : AC 100/110/120/220/230/240V 50-60Hz Power input : 200VA (normal), 400VA (max) Dimensions 21.5” (W) x 21” (D) x 23.5” - 25” (H) Weight 70 lbs Retinal Layers Identifi ed Macula: ILM, IS/OS, RPE, Bruch’s Membrane Glaucoma: RNFL Capture PC and Review Station Specifi cations Platform IBM PC/AT compatible CPU Pentium 4 or higher Memory 4GB or higher *2GB or higher for review station OS Microsoft Windows® XP Professional Hard Disc 500 GB* or higher *80 GB required for Review Station Software Display SXGA 1280 x 1024 32-bit color Graphics Board VRAM 256MB or higher *512MB preferred

Warranty & Returns

90 Day