Tomey TMS-5 Topographic Modeling System

Tomey TMS-5 Topographic Modeling System

Brand:   Tomey
Condition:   New
TMS-5 Topographic Modeling System * Anterior and posterior analysis of cornea * Scheimpflug images without a dark room * With a very short image capture time of 0.5 seconds * Comprehensive analysis applications * Support of the conventional TMS exam data
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Rapid measurements with Scheimpflug In the Scheimpflug mode, the TMS-5 can automatically capture multiple slices by focusing the alignment light on the center of the cornea as it does with Ring Topography. The time it takes to measure in this mode is approximately 0.5 to 1.0 seconds. This is very similar to the measurement time of the Ring Topography. Scheimpflug images without a dark room Since the slit light used in the Scheimpflug mode is emitted inside the cone, similar to the conventional TMS models, the TMS-5 is capable of capturing an image without a darkroom. Precise analysis By merging both the Ring Topography and the Scheimpflug topography, more accurate and reliable results can be achieved. This method eliminates the mis-trace that you would sometime see with the conventional TMS device. Rapid measurements with Ring-Topography In Ring-Topo mode, the TMS-5 acquires a measurement by aligning the refraction of the laser light on the center of the first mire ring automatically. The unit avoids the offset of the aligment in addition to the patient blinking problems with a very short image capture time of 0.5 sec Supports conventional TMS Exam Data Link and import utilities allows you to access any patient data from any TMS database in order to view it and compare it with the latest patient images and data from the TMS-5 Advanced IOL calculation The TMS-5 plus OKULIX is perfect combination for calculating the optical properties of the human eye utilizing numerical ray tracing. It allows a fast and easy selection of interocular lenses compared to the eye´s axial length.

Tech Specs

Measuring unit Ring Topographer Measurement type Light cone Measurement time 0.5 sec. / image (4 images maximum / each eye) Ring numbers 25 or 31 Measurement range (mm) 5.5 - 10.0 (Spherical) Measurement accuracy (mm) 0.02 (Spherical) Minimum / Maximum ring diameter (mm) 0.35 - 10.7 / 0.45 - 11.7 (25 rings / 31 rings) Minimum / Maximum ring diameter (43D) (mm) 0.46 - 8.8 / 0.57 - 10.9 (25 rings / 31 rings) Measurement points 6,400 / 7,300 maximum (25 rings / 31 rings) Measurement points on a ring 256 Alignment Manual with auto-correction Image capturing Auto / Manual Slit scan image (Scheimpflug) Measurement type Scheimpflug Scan speed 64 flames / 1.0 sec (Default) 32 flames / 0.5 sec Observation range (mm) 13.6mm Measurement points 40,960 maximum (640 points x 64 flames) Image capturing Auto / Manual Alignment monitor 6.4 inches color LCD Optical head Front-rear 50mm / Left-right 90mm / Up/down 40mm Chin rest 70mm Dimensions (mm) 268(w) X 513 (d) X 505 (h) Weight(Kg) 19 Power source AC100 to 240 V 50/60Hz 110-130VA Class 1 Type B Pc minimum requierements OS Windows XP CPU Intel Core2 Duo processer Memory 4Gb Video Video memory: 512Gb / OpenGL supported graphic card/ Resolution 1024 x 768 Storage HDD 640Gb / Cd-Rw Ports USB 2.0 / LAN (RJ-45)

Warranty & Returns

One Year