The Rad-8 uses Masimo SET pulse oximetry to provide accurate readings even during patient movement or in low-perfusion situations, and to reduce false alarms by up to 95%. This unit features a large, easy to read color display and a simple to use interface for quick setup and alarm management. The compact and lightweight design is perfect for acute and alternative care settings such as long-term care facilities, homecare, and sleep labs. Features and Benefits Sleep mode with 2 second averaging for bedside studies. Home mode for safe and accurate in-home monitoring and trending. RadNet and RadLink Interface capability for multi-patient remote monitoring. Perfusion Index (PI) indicates arterial pulse signal strength and may be used as a diagnostic tool during low prefusion. Low Signal IQ (SIQ) indicator highlights conditions of low signal quality. FastSat technology tracks rapid changes in arterial O2 with high fidelity unlike any other pulse oximeter. Nurse call interface. 72 hours of trending memory. Up to 7 hours of internal battery life when fully charged. Compatible with Philips Vuelink device interface module. APOD (Adaptive Probe Off Detection) provides the best off probe detection of Masimo's 3 sensitivity modes (ADOP, Normal, and MAX sensitivity). Adjustable averaging from 2 - 16 seconds. Audible and visual alarms for SpO2, PR, sensor condition, system failure, and low battery. Comes in vertical configuration.
Materials Included Rad-8 Pulse Oximeter 1 Adult Reusable Sensor 1 LNCS SpO2 Patient Cable 1 Power Cord User Manual
Technical Specifications Performance Measurement Range SpO2: 1-100 % Pulse Rate: 25 – 240 (bpm) Perfusion Index: 0.02% – 20% Saturation Accuracy Saturation: 60% to 80% No Motion Adults, Infants, Pediatrics: ± 4 digits Saturation: 70% to 100% No Motion Adults, Pediatrics: ± 2 digits Neonate: ± 3 digits Motion Adults, Pediatrics: ±3 digits Neonate: ±3 digits Low Perfusion Adults, Pediatrics: ± 2 digits Neonate: ± 3 digits Pulse Rate Accuracy Pulse Rate: 25 – 240 bpm No Motion Adults, Pediatrics, Neonate: ± 3 digits Motion Adults, Pediatrics, Neonate: ± 5 digits Low Perfusion Adults, Pediatrics, Neonate: ± 3 digits Resolution Saturation (%SpO2): 1% Pulse Rate (bpm): 1 bpm Electrical AC Power requirements: 100-240 VAC, 47-63 Hz Power consumption: 20 VA Max Batteries Handheld Type: Sealed lead acid Capacity: Up to 7 hours Charging Time: 8 Hours Environmental Operating Temperature: 41°F to 104°F (5°C to 40°C) Storage Temperature: -40°F to 158°F (-40°C to 70°C) Operating Humidity: 5% to 95%, non-condensing Operating Altitude: 500 mbar to 1060 mbar pressure -1000 ft to 18,000 ft (-304 m to 5,486 m) Physical Characteristics Dimensions 8.2” x 6” x 3” Weight: 2.1 lbs Modes Averaging Mode: 2, 4, 8,10, 12, 14 or 16 seconds Sensitivity: APOD, Normal and Max Alarms Audible and visual alarms for high and low saturation (1% to 100%), pulse rate (25 - 240 bpm), sensor condition, system failure and low battery Alarm volume High: 85dB (min) Low: 45dB (min) Display/Indicators Data Display: % SpO2 Alarm Status Alarm Silenced Status AC Power Signal IQ/Pleth Bar Perfusion Index Bar Battery Status No Sensor Sensor Off Display Type: LED
Please Inquire
1-Year Warranty