AP-7000 Automatic Perimeter

AP-7000 Automatic Perimeter

Brand:   AP
Condition:   New
Kowa's extensive normative database considers both the central field and the periphery thus ensuring consistent, accurate assessments when using a Kowa AP-7000 perimeter.
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

30 Years of Perimeter Experience, and It Just Got Better! AP-7000 Kowa's extensive normative database considers both the central field and the periphery thus ensuring consistent, accurate assessments when using a Kowa AP-7000 perimeter. Full threshold modes offer macular, central, and peripheral coverage up to 80°, while screening modes provide swift evaluation of the visual field. To shorten test times, quick modes are available for both threshold and screening modes. Static perimetry can be linked with fundus images from cameras, OCT, and SLO to define specific test locations on the retina. With its ergonomic, compact design, the AP-7000 offers additional comfort to patients, easy operation for the clinician, and fits perfectly within the practice. Features and Benefits Database of Normal Eyes Database of Normal Eyes Normative database allows for more precise test results. Kinetic Perimetry Kinetic Perimetry Kinetic perimetry is included as standard. Fundus Oriented Perimetry Static perimetry tests can be applied to areas of interest on fundus images taken from a retinal camera, OCT, or SLO. Threshold test within the central 10°, custom optional threshold test that allows selection of any desired test points, and custom optional screening tests are available. Fundus Oriented PerimetryFundus Oriented Perimetry Photo : Kanazawa University Department of Ophthalmology (Shinji Ohkubo, M.D. and Kazuhisa Sugiyama, M.D.) Threshold In addition to central 30° used to observe the progression of glaucoma, other tests are available such as central 10° which can identify visual field abnormalities in the macula. Clear Display of Analysis Results Clear Display of Analysis Results Analysis Indices GHT (Glaucoma Hemifield Test) For this index, threshold central test points are divided into 10 sectors, and corresponding sectors above and below the axis of the horizontal median are compared. VFI (Visual Field Index) A percentage index in which a normal visual field is 100% , and total loss of visual field is 0% Anderson's Criteria Diagnostic Support Function This criteria is for glaucomatous visual field defect. If any of the following conditions are satisfied, the colors turn orange. - PSD has p<5% - GHT is outside normal limits - Pattern deviation probability plot shows a cluster of 3 or more nonedge points that have p<5%, and one of the points has p<1% (The physician must judge whether the 3 points match the travel of NFL.) Chronological Change Display Test result analysis indices can be graphically displayed as time series data to give a clear grasp of changes over time in the tested eyes. Chronological Change Display Predictive Display Predictive graphs are displayed from calculations of linear rates of changes in analysis indices. This function predicts what values of MD and VFI will be reached at what age, if current rates of change in those values continue. Convenient Tabbed User Interface Main operation buttons are grouped at the top of the page, and buttons are laid out to follow the progression of tests, from patient information entry through test program selection to result display. Convenient Tabbed User Interface Screening 4-zone measurement that goes beyond screening, and programs using probability values (p-values), are among the features that enable effective testing in less time. Screening Running tests with probability value (p-value) intensities makes it possible to display the difference between the measured value and the normal value for each age range as a p-value, so that the evaluation equivalent to total deviation in thresholds can be performed in a shorter time. Isopter Isopter "Automatic measurement function", using many median patterns, "Manual measurement function", allowing free drawing of isopters, and "auto + manual measurement function", which allows any drawing of median after automatic measurement, are among the diverse measurement method options available. Supported Languages English Chinese French German Italian Portuguese Russian Spanish Japanese Structure and Function Fundus Oriented Perimetry Perform perimetry tests on fundus images Isopter AP-7000 2°spacing can find small VF defects Isopter Standard Automated Perimetry(SAP) 6°spacing (the photo is for illustrative purpose only) Integration of Structure and Function Provides a More Accurate Interpretation of VF Results Integration of Structure and Function Provides a More Accurate Interpretation of VF Results AP-7000 2°spacing can find small VF defects Decibels, deviation maps, probability plots can be integrated with your patients fundus images. RGC displacement Display with RGC displacement RGC displacement Photo: Kanazawa University Department of Ophthalmology (Shinji Ohkubo, M.D. and Kazuhisa Sugiyama, M.D.) AP-7000 2°spacing can find small VF defects Reference Sjostrand, J., Popovic, Z., Conradi, N., & Marshall, J. (1999). Morphometric Study of the Displacement of Retinal GanglionCells Subserving Cones Within the Human Fovea. Graefe's Archives for Clinical and Experimental Ophthalmology, 237, 1014-1023. Historical VF Results Data from various threshold instruments can be imported. The imported tests ensure that your patients VF history is maintained.

Tech Specs

Specs Dimensions 730 (W) x 430(D) x 700(H) mm Weight 26kg Stimulus Presentation Method Projection Stimulus Color White, Red, Blue Green Stimulus Size Goldmann I, II, III, IV, V Maximum Stimulus Intensity 3,183 cd/m² (10,000 asb): White Stimulus Presentation Time 0.2 Sec. Stimulus Presentation Interval 0.6-3.3 Sec. (Automatically Adjusted) Background Intensity White: 10cd/m² (31.5 asb) Yellow: 100 cd/m² (314.2 asb) (Automatic Light Adjustment) Examination Distance 300mm Meaurement Range 80° External Interface USB, Ethernet Fixation Target Orange LED Center: 1 Point, Auxiliary: 4 Point Fovea Examination: 4 Point Eye Fixation Monitoring Heijl Krakau Method, Eye Fixation Monitor, Gaze Monitor Printout USB-Connected Printer (sold seperately) Operation Screen Touch Panel Color LCD Monitor Operation Support Oral Instructions Chin Rest Operation Motor-driven Screening Program Standard, Precision, Center, Periphery, Glaucoma, V. Meridian, Center #1, Center #2 Screening Method 2 Zone, 3 Zone, 4 Zone, Quantity Scotoma Intensity Step: 5dB/Probability Variable (p-value) Quick Mode Available Supra Program Standard, Macula, Mariotte, Optional, D-Test Supra Method Same Intensity as 2 Zone Threshold Program Center 1, Center 2, Meridian, Macula 2, Periphery Threshold Method All Threshold, Quick 2, Super Quick Isopter Program Standard, Isopter + Screening 1, Isopter + Screening 2, Isopter + Threshold Isopter Method Auto, Manual Custom Program Circle Threshold, 1 Point Threshold, Quadrant Threshold, Optional Threshold#, Optional Threshold◯, Screening#, Screening◯ Perimetry on Fundus Perimetry Combined Fundus Image Fovea Examination Available in Threshold Center Examination (Threshold-Center 1, Center 2, Isopter + Threshold) Analysis for Threshold Each Examination Static Perimetry, Kinetic Perimetry, Blue-on-Yellow, Comparison to Age Related Normative Data, Four Color Stimulus: Red, Blue, Yellow, White, Golmann Size I-V Stimulus Analysis for Threshold Chronological Changes All Analysis Data: Scale, Threshold, Total Deviation p-value, Pattern Deviation p-value, Bebie Curve Graphically Displays: MD Comparing Comparison can be made between results of threshold screening or supra examination executed twice Combination Center, periphery, and isopter examinations can be combined in threshold and screening center examinations. Display Both Eyes Results of the examination of both eyes of the same patient executed on the same day are displayed side by side Display Multi Results of the examination executed four times (both eyes/either eye) of the same patient are displayed side by side Database Patient ID List Display, All List Display, Search Function, ID Extraction Function Patient Information ID, Name, Date of Birth, Sex, Correction, Visual Acuity, Diagnosis, Doctor, Comments Data Save Built-in Flash Memory, Capacity: For Approximately 20,000 Patients (40,000 Examinations Normal Eye Database Ver.1.0.0.0 Issued on 2011/06/09 Age Range: 20s to 70s Samples: 612 persons Criteria: Questioning, Visual Acuity, Reflection Power Supply Input: AC 100-230V 50/60 Hz Power Consumption: 200VA