Feature Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room. Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate). 10.4’’ color TFT LCD screen, lightness and volume are adjustable independently. Streamlined outline design with sense of the times & foldable handle. Multi-language interface selection: English, Spanish, Portuguese, Polish, French, Chinese, Arabic, Russian, Italian, Turkish, etc. User-friendly and man-machine dialogue interface with pop-up menus, dialogue boxes, rotary mouse and etc. Low-power consumption design with standby mode, rechargeable high-energy built-in battery. Advanced digital technology, accurately measure SpO2 in low perfusion situation. Drug calculation, ST-segment detection, pace maker and arrhythmia analysis. display format include OxyCRG diagram, 7-lead ECG waveform, big-font mode simultaneously ; can store 5 kinds of user-defined display format; Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower. Suitable for adults, pediatrics and neonates Applications in bedside and delivery monitoring; Widely used in patient room, emergency room, operation room, PACU, ICU, CCU, etc. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible. Printing of data, waveform, trend tables and trend diagram. Optional CO2 detection function
ECG Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ± 1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10% NIBP Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%, IBP Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable) Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 % Temperature Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ℃~ 45.0℃ Accuracy: ± 0.2 ℃ Response time: ≤ 3 min. SpO2 Display type: Waveform, data Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm Pulse Rate Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2% Trend review: Can Review history data of 360 hours CO2: Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5﹪ Measured values) 10﹪(>5﹪ Measured values) Environment Temperature: (+5 ~ +45)℃; Operation & Storage: (-20 ~ +55)℃ Relative humidity : ≤ 80 % Operation & Storage:≤ 93 % Atmospheric pressure: (700 ~ 1060)hPa Operation & Storage:(500 ~ 1060)hPa Adapt to power: (100 ~ 240)V a.c. 50/60Hz, Maximum input power: 80VA Fuse: T 1.6 A Continuous working time: Network power working time : ≥ 8 hours Internal power continuous working: > 1 hour (In premise of full battery, and measuring blood pressure every 10 minutes) Signal Interface:( External monitor): standard VGA port (optional) PRINTER(External printer): PC/AT Parallel Interface NET (External central monitor): RJ45 port LINE(External telephone line): MODEM port
30 days
18 months warranty, 30 days return policy