Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely. ◆ Streamline outward appearance design, High-lightness LED digital tube display ◆ Easy operation with rotated mouse ◆ Low power design, rechargeable high-energy built-in battery. ◆ Fast and accurate measurement of blood pressure, a function of venous-puncture ◆ Using advance Analog technology, accurately measure the Spo2 in low perfusion situation. ◆ Audible & visual alarm available and alarm limits are adjustable. ◆ Suitable for adults, pediatrics, neonates. ◆ Application in hospital like emergency pre-and post-operative care, theater\operating room, intermediate care\step down units, labor and delivery, hospital-based special procedure areas and outdoor ambulance surgery. ◆ Communication functions to network with central monitoring system.Long-distance monitoring and software upgrade
Main Feature 1. Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely. 2. Streamline outward appearance design, High-lightness LED digital tube display 3. Easy operation with rotated mouse 4. Low power design, rechargeable high-energy built-in battery. 5. Fast and accurate measurement of blood pressure, a function of venous-puncture 6. Using advance Analog technology, accurately measure the Spo2 in low perfusion situation. 7. Audible & visual alarm available and alarm limits are adjustable. 8. Suitable for adults, pediatrics, neonates.
Specification NIBP Test principle Automatic oscillometric Patients types Adult、pediatric、and neonate Measurement parameters, systolic mean, diastolic Measurement type Manual、automatic、and continuous Measurement rang 15-300mmHg Units of measurement mmHg/kPa optional Accuracy ±2 mmHg Respiration Measurement range:0 BPM- 120 BPM Accuracy :±1 BPM or ±5 % Body temperature Measurement range 20.0~45.0℃ Display T1、T2 Units of measurement: ℃/℉ optional Accuracy ±0.1℃ Spo2 Measurement range 0-100% Resolution 1% Pulse rate range 30-250 BPM Accuracy ±2% Standard parameter: Respiration+ Temperature+NIBP+Spo2(Built in rechargeable battery) Environmental Specifications Operation Temperature:5 to 45℃ Relative humidity: ≤ 80 % Air pressure:70 to 106 kPa Transport and Storage: Temperature:-20 to 55℃ Relative humidity ≤ 93% Air Pressure:50 to 106 kPa Input voltage:100 to 240 V Frequency:50/60 Hz Power:80VA Operation time:≥ 8 hours Internal battery:≥ 1 hour Connectors of signs CRT: Standard VGA connectors NET: RJ45 connectors
30 days
18 months warranty, 30 days return policy