• Sign In
  • Sign Up
Stores And Market
Need Help? Call Our Experts 1-800-303-2996
Enhanced Medical Services (EMS)
Optovue RTVue OCT (Pre-Owned)

Optovue RTVue OCT (Pre-Owned)

Brand:   Optovue
Condition:   New
The Used Optovue RTVue Optical Coherence Tomographer
Quantity:
Have a question? Feel free to Ask a question
Please Sign In To Inquire Price
If you just logged in, please refresh the page

Details

Weight 250.0000 lbs The Used Optovue RTVue Optical Coherence Tomographer Features: Fourier-Domain Optical Coherence Technology High Resolution Retinal Imaging Real-Time Eye Tracking Vitroretina Imaging Deep Choroid Imaging (DCI) Advanced clinic scan protocols, designed by OCT thought leaders: Retinal scan patterns: High Definition B-Scan Speckle Less Image Horizontal and vertical views Dense thickness/elevation maps Fast raster scan 3D retinal animation 1 3D retinal animation 2 3D, B-Scan, C-Scan and SLO images Glaucoma Scan Patterns:(protocol of AIG Study, http://www.aigstudy.net) Disk/rim/cup contours and RNFL thickness map Inner retinal thickness & Superior/Inferior 3.45mm diameter RNFL thickness with progressive/asymmetry analysis Benefits The founders of Optovue have hands on experience on the development of all three previous and current generations of ophthalmic OCT products. RTVue is designed with the goal to advance the retinal diagnosis for routine clinic use in mind. RTVue overcomes all StratusTMOCT short comings with following new features: Ultra-high speed: 65 time faster (26,000A-scan/s) for 3D and high density mapping High Resolution: Twice the resolution (5µm) than StratusTM OCT Two scan depth range: 2mm for imaging the macular and 2.3mm for imaging a tilt disk. Two image modes: Vitreo mode: for better vitreoretinal tissue image Choriod mode: for better chorioretinal tissue image High transverse scan resolution: 15µm (1/e2 spot size on retina) Video fundus image: Fundus camera optical design for high quality NIR retina image Non-mydriatic imaging: The pupil size required for the fundus image is 3.0mmLong working distance: 22mm from cornea to ocular lens

Tech Specs

RTVue Scanner: OCT Image: 26,000 A-scan/second Frame Rate: 256 to 4096 A-scan/Frame Depth Resolution (in tissue) : 5.0µm Transverse Resolution: 15µm Scan Range: Depth: 2- 2.3mm Transverse: 2mm to 12mm Scan Beam Wavelength: λ=840±10nm Exposure Power at pupil: 750µW Fundus Imager: FOV: 32° (H) x 23° (V) Minimum Pupil diameter: 3.0 mm Illumination: Near IR Patient Interface: Working Distance: 22mm Motorized Focus Range: -15D to +12D Computer Unit: CPU: 2.66 GHz Quad-Core Processor RAM: 4GB Foot print: 1010mm(W) x 520mm(D)